Electrolysis Water Biofuel Cell Chlor-alkali PEM N417
-
$850.00≥5 Square Meter
- Min. Order:
- 5 Square Meter
- Min. Order:
- 5 Square Meter
- Transportation:
- Ocean, Land, Air, Express, Express
- Port:
- shanghai , shenzhen, guangzhou
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | China |
---|---|
Payment Type: | L/C,T/T,D/P,D/A,Paypal,Money Gram,Western Union,D/A |
Incoterm: | FOB,CFR,CIF,EXW,FAS,FCA,CPT,CIP,DEQ,DDP,DDU,Express Delivery,DAF,DES |
Certificate: | MSDS ISO |
HS Code: | 3921909001 |
Transportation: | Ocean,Land,Air,Express,Express |
Port: | shanghai ,shenzhen,guangzhou |
Electrolysis Water Biofuel Cell Chlor-alkali Soda Precious-metals Recovery Electrolyzer PEM PFSA membrane N417
Like following as Trivalent chromium diaphragm plating method
An electroplating method for trivalent chromium diaphragm belongs to the technical field of electroplating. The process steps are as follows: the electroplating chamber is separated into two parts: cathode chamber and anode chamber by ion exchange membrane; Trivalent chromium plating solution was injected into the cathode chamber, acidic or neutral electrolyte was injected into the anode chamber, and then trivalent chromium plating was carried out. It can eliminate the formation of hexavalent chromium and chlorine on the anode during the trivalent chromium plating process. Only oxygen precipitation reaction occurs on the anode, the advantage is that it can completely overcome the environmental pollution caused by the precipitation of anode chlorine gas and the formation of hexavalent chromium, and the negative effects such as poor stability of the plating solution, which is conducive to promoting the application of trivalent chromium plating technology.
N-41ptfe series composite ion membrane has the property of cationic one-way passage. Due to the use of high-strength ptfe mesh cloth as the support layer, with the most suitable molecular weight and ion exchange capacity of perfluorosulfonic acid resin, it has the characteristics of super chemical resistance and durability.
Perfluorinated ion membrane n-41ptfe series is a composite perfluorinated ion membrane H type of perfluorinated sulfonic acid produced by korun company by steel strip casting method. Perfluorinated ionic membrane as the separation of Yin and Yang in all kinds of cell and battery very solid electrolyte, membrane has the property of unidirectional by cation, and because of the high strength as support layer ptfe mesh cloth, with the most appropriate molecular weight and ion exchange capacity of perfluorinated sulfonic acid resin, N-41 series compound perfluorinated ionic membrane has the characteristics of strong chemical resistance and durability. It is widely used in chlor-alkali industry, hydrogen production by electrolysis water, chlorine dioxide generator, amino acid refining, gold salt preparation, copper recovery by etching solution, electroplating and other fields.


Specification:
Thickness and weight
Type |
Thickness (μm) |
Weight (g/m2) |
N-417 |
260 |
340 |
N-4110 |
360 |
470 |
Performance Index
Physical Properties |
Technical Index |
Test Method |
Tensile Strength (MPa) |
50 |
ASTM D 882 |
Elongation at break (%) |
120 |
ASTM D 882 |
Specific Gravity |
1.35 |
— |
Other properties |
Technical Index |
Test Method |
Conductivity (S/cm) |
0.083 |
GB/T 20042.3-2009 |
Acid Capacity (meq/g) |
1.00 |
GB/T 20042.3-2009 |
Hydrolytic Properties |
Index Parameters |
Test Method |
Water Content (%) |
5.0±3.0 |
ASTM D570 |
Water Uptake (%) |
50.0±5.0 |
ASTM D570 |
Thickness Change |
5 |
ASTM D756 |
Thickness Change |
10 |
ASTM D756 |
Linear expansion |
2 |
ASTM D756 |
Linear expansion |
5 |
ASTM D756 |
2.Conductivity measurements a 23 °C, 100% RH.
3.A base titration procedure measures the equivalents of sulfonic acid in the polymer, and uses the measurement to calculate the acid capacity or equivalent weight of the membrane.
4.Water content of membrane conditioned to 23 °C and 50% RH (dry weight basis).
5.Water uptake from dry membrane to conditioned in water at 100 °C for 1 hour (dry weight basis)
Application:
chlor-alkali industry, hydrogen production by electrolysis water, chlorine dioxide generator, amino acid refining, gold salt preparation, copper recovery by etching solution, electroplating and other fields.
Packing:
Description: the supply size of the film is based on dry film products, at 23℃ and 50% relative humidity. The humidity and temperature of the air will affect its size. The products that need to be pretreated by our company are guaranteed to be of positive tolerance, and the products that need to be pretreated are all sheet materials.
Film packaging, the use of the volume, less than the volume of no core, a larger number of containing the core. Since the size of perfluorinated ion films will change under different temperature and humidity, perfluorinated ion films are all protected by hard protective film to facilitate the stability of MEA spraying and size reduction. The outer packing is packed in plastic drums or hard cartons.
Please contact the sales staff for special size and packing.
Related Keywords